Pelco DX9100 Manuel d'utilisateur Page 80

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 86
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 79
80 C636M-E (4/05)
Figure 101. CM9760-REL Configuration Dialog Box
7. Set the baud rate to 9600 and the parity to Even. The relay unit should have these same settings.
8. Enter the COM Port number. This is the port on the viewstation that connects to the relay unit.
9. Change the default latch time. This time activates the relays on the relay unit and sets the same latch time for all of the
relay ports. The default is 5 seconds.
NOTE: Frame Address is not used. The default value is 0.
10. Add latch times for specific relays.
11. Click OK.
12. Click Test.
13. Click OK on the Server Alert Configuration screen.
6. Click Configure. The following dialog box appears.
Vue de la page 79
1 2 ... 75 76 77 78 79 80 81 82 83 84 85 86

Commentaires sur ces manuels

Pas de commentaire