C662M-E (5/03) 41
Table B. Security Levels
Priority Event Definition Example
0 Critical Controller is dead. System is disconnecting from this controller.
Controller is gone. System is disconnecting from this controller.
Bad blocks found.
Controller is using default non-unique world-wide name.
Mirror race on critical drive.
1 Serious A hard disk has failed.
Physical drive missing on startup.
Fan failure.
Over temperature.
Power supply failure.
Uninterruptible power supply failed.
Back end SCSI bus dead.
Controller firmware mismatch.
Controller Boot ROM Image needs to be reloaded.
Lost connection to server, or server is down.
2 Error Rebuild stopped because logical drive failed.
Expand capacity stopped with error.
Consistency check on logical drive error.
Logical drive is critical.
Logical drive initialization failed.
Data for disk block has been lost due to logical drive problem.
Write back error.
Mirror race recovery failed.
3Warning New configuration.
Controller entered conservative cache mode.
Controller has been reset.
Enclosure access critical.
Uninterruptible power supply battery low.
SCSI command timeout on hard device.
4 Informational Initialization started.
Logical drive background initialization started.
Fan has been restored.
Power supply has been restored.
Access to temperature sensor has been lost.
Access to fan status information has been lost.
Uninterruptible power supply normal.
Storage works enclosure reported normal state.