Digital Video RecorderDX8100DX8100-ISCI SCSIand DX9200HDDIInstallation ManualC2635M (1/07)
10 C2635M (1/07)6. Ensure that the DX8100 Series DVR and all of its components are protected against ESD. Before handling any electronic components, y
C2635M (1/07) 11Figure 5. Removing Chassis CoverUNDERSTANDING THE DX8100 COMPONENT LAYOUT Figure 6 and Table D provides information about the DX8100’
12 C2635M (1/07)MOVING THE MAIN CAPTURE CARD TO SLOT 3In the DX8108 and DX8116 base DVRs, the main Capture Card is installed in slot 2. To install the
C2635M (1/07) 13Figure 8. Moving Main Capture CardINSTALLING THE DX8100 SCSI CARD The DX8100-ISCI SCSI card is shipped separately. For information ab
14 C2635M (1/07)REASSEMBLING THE UNIT 1. Replace the chassis cover using the screws you removed from the side and rear of the unit. Refer to Figure 10
C2635M (1/07) 15Setting Up the DX9200HDDIThis section describes how to install the hard drives in the DX9200HDDI and configure the DX9200HDDI to opera
16 C2635M (1/07)CONFIGURING THE DX9200HDDIThe DX9200HDDI is configured to operate in one of two ways: • RAID 5: RAID 5 (redundant array of independent
C2635M (1/07) 17CONFIGURING A SINGLE RAID LEVEL 5 ARRAYTo configure a single RAID Level 5 array: 1. Power up the DX9200HDDI. For information about pow
18 C2635M (1/07)h. Press ! to select YES. The entry is confirmed and the 21 Array 1 menu item is redisplayed. Figure 14 shows the button selections an
C2635M (1/07) 196. To update the NVRAM with the new settings, do the following:a. Press Exit until the Main menu is displayed. b. Press !" to scr
20 C2635M (1/07)8. After the DX9200HDDI single array is initialized, the DX9200HDDI must be connected to the DX8100, then the DX8100 must be configure
C2635M (1/07) 21CONFIGURING A SINGLE RAID LEVEL 5 ARRAY WITH HOT SPARETo configure a single RAID Level 5 array with hot spare: 1. Power up the DX9200H
22 C2635M (1/07)6. To update the NVRAM with the new settings, do the following:a. Press Exit until the Main menu is displayed. b. Press !" to scr
C2635M (1/07) 23CONFIGURING TWO RAID LEVEL 5 ARRAYSTo configure two RAID Level 5 Arrays: 1. Power up the DX9200HDDI. For information about powering up
24 C2635M (1/07)6. Press Exit until the Main menu is displayed. 7. To configure array 2, do the following: a. Press !" and scroll to 2 RAID Param
C2635M (1/07) 2511. To start the initialization process, do the following:a. Press !" to scroll to 63 Restart. b. Press !. The 63 Restart menu is
26 C2635M (1/07)5. To update the NVRAM with the new settings, do the following:a. From the Main menu, press !" to scroll to 6 NVRAM.b. Press !. T
C2635M (1/07) 27CONFIGURING TWO RAID LEVEL 5 ARRAYS WITH HOT SPARETo configure two RAID Level 5 Arrays with one hot spare:1. Power up the DX9200HDDI.
28 C2635M (1/07)7. To configure array 2, do the following: a. Press !" and scroll to 2 RAID Params.b. Press !. The 2 RAID Params menu is displaye
C2635M (1/07) 2911. To start the initialization process, do the following:a. Press !" to scroll to 63 Restart. b. Press !. The 63 Restart menu is
C2635M (1/07) 3ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30 C2635M (1/07)4. Press Exit until the Main menu is displayed. 5. To update the NVRAM with the new settings, do the following:a. From the Main menu,
C2635M (1/07) 31DELETING ARRAYSIn the event that the DX9200HDDI needs to be reconfigured, this section describes how to delete arrays. In this case, t
32 C2635M (1/07)6. To update the NVRAM with the new settings, do the following:a. From the Main menu, press !" to scroll to 6 NVRAM.b. Press !. T
C2635M (1/07) 33DELETING TWO ARRAYSTo delete two arrays:1. Verify that the RAID is not being used by any devices (DX8100).2. On the DX9200HDDI control
34 C2635M (1/07)6. Press Exit until the Main menu is displayed. 7. To delete the RAID level for array 2, do the following:a. From the Main menu, press
C2635M (1/07) 35Connecting the DX8100 to the DX9200HDDIThe DX9200HDDI can support one or two DX8100 DVRs (refer to Figure 20 and Figure 21). The optio
36 C2635M (1/07)Configuring the DX8100 to Access the DX9200HDDIThis section describes how to configure the DX8100 to recognize the DX9200HDDI external
C2635M (1/07) 37b. Select the Explore option. The Start Menu opens.c. Right-click My Computer. Select Manage.Figure 24. My Computer Quick Menud. The
38 C2635M (1/07)e. Select the Disk Management folder. The Write Signature and Upgrade Disk Wizard opens.f. Click Next. The Write Signature and Upgrade
C2635M (1/07) 39i. Click Next. The Select Disks to Upgrade dialog box opens.j. Click the check box to select each drive that you want to upgrade.Figur
4 C2635M (1/07)List of Illustrations 1 DX8100 SCSI Card and DX9200HDDI Storage Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40 C2635M (1/07)Figure 30. Unallocated Space Shortcut Menub. Select Create Partition. The Create Partition Wizard opens.Figure 31. Create Partition
C2635M (1/07) 41c. Click Next. The Select Partition Type dialog box opens.Figure 32. Select Partition Dialog Boxd. Select Primary Partition and then
42 C2635M (1/07)e. Click Next. The Assign Drive Letter or Path dialog box opens.Figure 34. Assign Drive Letter or Path Dialog Boxf. Click Next. The F
C2635M (1/07) 43h. Click Finish. The new drive appears in the device list.Figure 36. Completing the Create Partition Wizardi. Right-click the new dri
44 C2635M (1/07)b. Type Allocreset.exe in the Open text box.c. Click OK. The Allocation Management dialog box opens.Figure 38. Allocation Management
C2635M (1/07) 45d. For each drive listed, select the Allocation option from the drop-down menu.Figure 41. Selecting Allocation Option for Each Drivee
46 C2635M (1/07)CONFIGURATION INSTRUCTIONS FOR STORAGE ARRAYS ABOVE 2.0 TBTo initialize storage beyond 2.0 TB:1. To exit the DX8100 application if it
C2635M (1/07) 47d. The Computer Management window opens.Figure 48. Computer Management Windowe. Select the Disk Management folder. The Write Signatur
48 C2635M (1/07)g. Click Next. Select Disk to Write Signature dialog box opens.h. Click the check box to select each disk for which you want to write
C2635M (1/07) 49k. Click Next. The Completing the Write Signature and Upgrade Disk Wizard opens.Figure 52. Completing the Write Signature and Upgrade
C2635M (1/07) 5 61 Allocation Management Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50 C2635M (1/07)b. Select Create Partition. The Create Partition Wizard opens.Figure 54. Create Partition Wizardc. Click Next. The Select Partition T
C2635M (1/07) 51e. Click Next. The Assign Drive Letter or Path dialog box opens.-Figure 57. Assign Drive Letter or Path Dialog Boxf. Click Next. The
52 C2635M (1/07)h. Click Finish. The new drive appears in the device list.Figure 59. Completing the Create Partition Wizardi. Right-click the new dri
C2635M (1/07) 53b. Type Allocreset.exe in the Open text box.c. Click OK. The Allocation Management dialog box opens.Figure 61. Allocation Management
54 C2635M (1/07)d. For each drive listed, select the Allocation option from the drop-down menu.Figure 64. Selecting Allocation Option for Each Drivee
PRODUCT WARRANTY AND RETURN INFORMATIONWARRANTYPelco will repair or replace, without charge, any merchandise proved defective in material orworkmanshi
Worldwide Headquarters3500 Pelco WayClovis, California 93612 USAUSA & CanadaTel: 800/289-9100Fax: 800/289-9150InternationalTel: 1-559/292-1981Fax:
6 C2635M (1/07)List of TablesA DX8100-ISCI Kit Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C2635M (1/07) 7IntroductionWelcome to the external video storage upgrade for the DX8100 Series digital video recorder (DVR). The video storage upgrade
8 C2635M (1/07)TOOLS NEEDED OTHER DX8100 OPTIONAL ACCESSORIESThe DX8108 base unit comes with an 8-channel Capture Card and the DX8116 base unit includ
C2635M (1/07) 9Installing the DX8100-ISCI SCSI CardThis section describes how to install the DX8100-ISCI SCSI card, and is organized into the followin